The M08-PRH89 series probes are designed for 0.8 mm standard and custom socket applications. The probe tube must be captured in the socket while the Interface Plunger remains compressed. The DUT Plunger is stroked with each actuation. The Interface Plunger is typically compressed and fixed at approximately .008. Due to thermal effects on the lubrication's kinematic viscosity, the operating temperature is -40 to 212 F [-40 to 100 C].
Probe Specifications
Mechanical
Full Stroke: DUT side .019 [.48]; Interface side .008 [0.20]
Working Stroke: up to .027 [0.69] (included both plungers)
Operating temp.: -40 to 212 F [-40 to 100 C]
Current rating (for single probe in ambient air with 70°F [20°C] rise): 4.5 Amps
|