Below is a summary of the various independent testing done on our integraMate ICO Series. Conctact QA for more information
Test Standard | Description | ICOA5 | ICO60 |
EIA 364-23B |
LLCR | <2.0 mΩ | <4.0 mΩ |
EIA 364-9C | Durability / 100,000 cycles | <1.0 mΩ change | <2.0 mΩ change |
EIA 364-37B | Engagement & Separation Forces |
1.0 oz gauge pin/4.0 oz mating pin/Bilaterally Equal | 1.0 oz gauge pin/2.0 oz mating pin/Bilaterally Equal |
EIA 364-31B | Cyclic Humidity | 240 hours / 10 cycles / 98% RH / 30k cycles preconditioning / <2.0 mΩ change | |
EIA 364-70A | Ratings | 12 Amps with 30°C rise (3 circuits energized) | 4 Amps with 30°C rise (7 circuits energized |
EIA 364-32C | Thermal Shock | -25°C to 105°C, 5 cycles <2.0 mΩ change | |
EIA 364-36A | Gas Tight | 1 hour exposure / <2.0 mΩ change | |
EIA 364-17B | Temperature Life | 250 hours @ 85°C / <2.0 mΩ change | |
EIA 364-27B | Mechanical Shock | 50Gs / <2.0 mΩ change / No discontinuity >1 microsecond | |
EIA 364-28D | Random Vibration | 19.64Grms / <2.0 mΩ change / No discontinuity >1 micorsecond | |
EIA 364-32C | Thermal Cycling | 0°C to 100°C, 250 cycles / <2.0 milliohm change |